Pre-release SerialFlow 0.9.0 beta 2 works, but has rough edges. Tell us what you find.

Example · MDX-400 motor-drive bench · Dashboards

A test-bench HMI, written as text

Describe the dashboard as text, paste it in, press Import. 33 widgets, live.

  • 33 widgets from one text file
  • One line binds: primary=F:7
  • Amber at 72 °C, red at 78 °C
  • An AI assistant can write it

The MDX-400 is a simulated motor drive. A script printed the serial lines its firmware would send, and SerialFlow read them exactly as if they came from a COM port. Your own board works the same way.

On the MDX-400 bench, graph F carried every number that mattered: speed, torque, bus current, temperatures, state of charge and three status flags. A graph is the wrong view for “is it running, is it hot, has it tripped?”, so the bench got one screen with the battery, the inverter and the motor side by side. Nobody placed its 33 widgets by hand: the whole canvas is a text file, imported in one step.

What the firmware prints

The canvas reads graph F, Bench telemetry. The firmware sets it up once with 14 lines, then prints one line per sample with all 13 values:

~{F:I:Bench telemetry:4000:S:T:R:Sample::0}
~{F:S:1:F32:R:Speed:rpm:0:4FC3F7}
~{F:S:2:F32:R:Setpoint:rpm:0:FFB74D}
~{F:S:3:F32:R:Torque:Nm:0:BA68C8}
~{F:S:4:F32:R:DC bus current:A:0:FFD54F}
~{F:S:5:F32:R:Pack voltage:V:0:81C784}
~{F:S:6:F32:R:Electrical power:W:0:4DD0E1}
~{F:S:7:F32:R:MOSFET:°C:0:F06292}
~{F:S:8:F32:R:Motor winding:°C:0:FF8A65}
~{F:S:9:F32:R:State of charge:%:0:64B5F6}
~{F:S:10:F32:R:Pack temp:°C:0:A1887F}
~{F:S:11:F32:R:RUN::0:69F0AE}
~{F:S:12:F32:R:DERATE::0:FFA726}
~{F:S:13:F32:R:FAULT::0:FF5252}
~{F:1:2200.5:2200:5.93:12.06:51.93:626:48.2:45.4:51.00:29.4:1:0:0}
…
~{F:1:2970.6:3000:0.00:40.97:50.60:2073:76.0:52.3:50.88:29.5:0:0:1}
…
~{F:1:2999.7:3000:10.96:30.16:51.07:1540:78.1:54.7:50.81:29.5:1:1:0}
LineFieldsMeaning
~{F:I:…}Bench telemetry 4000 S T R Sample (empty) 0Graph F: name, 4 000 points per signal, Streamer mode, time X axis, raw X display, X label, no X unit, no SI scaling
~{F:S:7:…}7 F32 R MOSFET °C 0 F06292Signal 7: 32-bit float sent as a real number, name, unit, no SI scaling, colour
~{F:1:…}13 valuesOne sample with automatic X; the values go to signals 1 to 13 in ID order

The flags (signals 11 to 13) carry 0 or 1. The second data line is the overcurrent trip: 40.97 A, RUN 0, FAULT 1. The third is the derate: MOSFET 78.1 °C, DERATE 1.

Set it up in SerialFlow

Write the dashboard as text

The canvas is the file canvas_motor_bench.txt: a header, optional canvas hints, then one block per widget. Here is its start and two of its 33 blocks:

=== SERIALFLOW CANVAS WIDGETS ===
Description: MDX-400 motor test bench - battery, inverter and motor synoptic bound to graph F (Bench telemetry)

--- CANVAS HINTS ---
Width: 1920
Height: 1080
BackgroundColorHex: 1A1D21
…
--- WIDGET: OnOffToggle ---
Label: FAULT
X: 1420
Y: 30
Width: 100
Height: 40
PrimaryColorHex: FF5252
BackgroundColorHex: 262C33
Binding: primary=F:13
Threshold: 1=FF1744
…
--- WIDGET: ArcGauge ---
Label: Speed
X: 1050
Y: 135
Width: 250
Height: 285
RangeMin: 0
RangeMax: 3500
UnitDisplay: rpm
DecimalPlaces: 0
PrimaryColorHex: 4FC3F7
BackgroundColorHex: 262C33
Binding: primary=F:1
…
=== END WIDGETS ===
LineMeaning
--- WIDGET: ArcGauge ---Starts a widget. The type key is one of the 35 types, for example ArcGauge, Sparkline, AlarmBanner
LabelThe widget’s title, and the only property you must give
X, Y, Width, HeightPosition and size in pixels
RangeMin, RangeMax, UnitDisplay, DecimalPlacesScale of a gauge or bar, unit text, decimals
PrimaryColorHex, BackgroundColorHexColours as six hex digits, without #
Binding: primary=F:1The signal: role primary, graph F, signal ID 1 from the ~{F:S:1:…} line
Threshold: 1=FF1744From the value 1 upwards, use this colour

The binding is the only link to the firmware: a graph letter and a signal ID. 22 of the 33 widgets carry one; the rest are titles, panels, frames, connectors and a run clock. Widgets can share a signal: F:7, the MOSFET, drives a banner, a linear gauge, a value card and a sparkline.

Import the text

  1. ☰ → Tools → New Canvas Dashboard. An empty 1920 × 1080 canvas opens as a new tab.
  2. Click Edit on the canvas toolbar. The Widget Toolbox and the widget list appear.
  3. Choose Import/Export ▾ → Paste AI Text…. If the clipboard holds text that starts with === SERIALFLOW CANVAS WIDGETS ===, the dialog is already filled in.
  4. Paste the text and press Import. SerialFlow confirms Imported 33 widget(s).
  5. Click Edit again to go back to run mode. The widgets update as soon as graph F data arrives.
Canvas Widgets AI Text dialog with the MDX-400 canvas text pasted in: header, canvas hints and the first widget blocks, with Copy to Clipboard, Import and Close buttons.
Paste AI Text: the bench file pasted in, one press on Import away from 33 widgets.

Let an AI assistant write it. The format is made for this: plain Key: value lines. Choose Import/Export ▾ → AI Format Reference and press Copy to Clipboard. You get a Markdown description of the format: all 35 type keys with their default sizes, every property with its default, the binding and threshold rules, and an example. Give it to your assistant with your firmware’s ~{…:S:…} lines, which hold each signal’s ID, name and unit, and describe the screen: an arc gauge for speed, value cards for pack voltage and state of charge, an alarm banner on the MOSFET, amber from 72 and red from 78. Paste the answer into Paste AI Text… and press Import. To rework a canvas, Import/Export ▾ → Copy as AI Text copies the selected widgets (or all) in the same format.

Thresholds that match the derate

The MOSFET alarm banner in the header carries two thresholds:

--- WIDGET: AlarmBanner ---
Label: MOSFET
…
Binding: primary=F:7
Threshold: 72=FFA726
Threshold: 78=FF5252

A threshold applies from its value upwards. SerialFlow checks them in list order and the last one reached wins, so list them from the lowest value to the highest: grey below 72 °C, amber from 72 °C, red from 78 °C. The limits are the bench’s own: the drive derates at 78 °C and releases below 72 °C, which the DERATE indicator shows from signal 12. The status indicators use one threshold at 1: FAULT is red when signal 13 is 1, grey when it is 0.

To change a limit, double-click the widget in edit mode. Widget Settings has four tabs: General, Appearance, Signals (role, graph, signal) and Thresholds, where Add Threshold adds a rule and × removes one. A rule is a threshold and a colour. It can also compare the minimum, maximum or average over the last N seconds instead of the value, trigger below the threshold instead of above, wait N seconds before it triggers, clear only a hysteresis below the threshold, and play a WAV or MP3 sound, once or repeated. On OK the widget shows the change at once.

The text file takes the same options after the colour. A red level that sounds an alarm when the MOSFET has averaged 78 °C or more for 10 s, and repeats it every 30 s until someone clicks Acknowledge on the canvas toolbar:

Threshold: 78=FF5252; statistic=Average; window=10; hold=10; sound=C:\Sounds\alarm.wav; repeat=30

Mute on the same toolbar silences every alarm sound; the status bar names each new alarm, with an Acknowledge button of its own.

Widget Settings for the alarm banner, Thresholds tab: range 20 to 100, above 72 in orange, above 78 in red.
The banner’s Thresholds tab: the two lines from the text file.

The result

Animation: a dark dashboard with battery, inverter and motor panels; gauges and trend lines move, a warning banner turns orange.
The canvas live: speed steps, a trip with FAULT in red, the restart and the derate.

The speed steps up to 3 000 rpm and the hill pushes the current to about 30 A. The MOSFET passes 72 °C: the banner turns amber. A 41 A spike trips the drive: FAULT red, RUN grey, current near 0 A. The drive restarts, the MOSFET passes 78 °C, DERATE comes on and the banner turns red.

Canvas in edit mode: the widget toolbox on the left, the bench dashboard in the middle with the speed gauge outlined, a list of 33 widgets on the right.
Edit mode after the import: the toolbox with all 67 types, the 33 widgets in the list, live values on the gauges and cards.

No time to design: the grid

The grid Signal Dashboard needs no layout. Open ☰ → Tools → Panel Configuration…, press + Dashboard, add a row per tile with + Add Widget (graph, signal, tile type, label, unit, colour, range) and press Create Now. Tiles fill 1 to 6 columns, in 8 types: numeric display, progress bar, radial gauge, text label, colour indicator, sparkline, on/off indicator and statistics. A tile can span several columns or rows, and + Threshold on its row adds the same kind of threshold rules as on the canvas, sounds included.

Grid of tiles with arc gauges, numbers, small trend lines and a red alert bar.
The same graph F as a grid Signal Dashboard: 16 tiles in 4 columns.

In your own firmware

The canvas needs nothing from your board but graph lines. Here is graph F with five of the 13 signals: speed, current, MOSFET, DERATE and FAULT.

#include <stdio.h>

/* Once after reset: graph F and the signals the canvas binds to */
void bench_graph_init(void)
{
    printf("~{F:I:Bench telemetry:4000:S:T:R:Sample::0}\n");
    printf("~{F:S:1:F32:R:Speed:rpm:0:4FC3F7}\n");
    printf("~{F:S:4:F32:R:DC bus current:A:0:FFD54F}\n");
    printf("~{F:S:7:F32:R:MOSFET:°C:0:F06292}\n");
    printf("~{F:S:12:F32:R:DERATE::0:FFA726}\n");
    printf("~{F:S:13:F32:R:FAULT::0:FF5252}\n");
}

/* Every control-loop tick: one line, values in signal-ID order */
void bench_graph_sample(float rpm, float amps, float t_mosfet,
                        int derate, int fault)
{
    printf("~{F:1:%.1f:%.2f:%.1f:%d:%d}\n",
           rpm, amps, t_mosfet, derate, fault);
}

IDs need not be consecutive: values go to the signals in ascending ID order. Keep the canvas file’s IDs and its Binding: lines fit unchanged.

Good to know

  • Import adds, it does not replace. Imported widgets join what is on the canvas. One Undo takes the whole import back; the canvas keeps 100 undo steps.
  • Canvas hints. Imported into an empty canvas, the hints set its size, background colour and grid; the same Undo takes them back. A canvas that already has widgets keeps its own settings.
  • Decimal dots. Numbers take a dot (0.5), whatever your Windows locale.
  • Edit while it runs. Edit on the canvas toolbar switches edit and run mode; the widgets update in both.
  • Canvas keys. Click into the canvas first: then F5 switches edit and run mode, Ctrl+S saves the canvas and Ctrl+Z undoes, also while it is docked in the main window. With the focus elsewhere, F5 and Ctrl+S keep their app meaning: connect the port, save the profile.
  • It comes back. Save writes the canvas to Documents\SerialFlow\canvas\. A canvas that was open when you closed SerialFlow opens again, docked where it was, and ☰ → Tools → Open Canvas Dashboard… opens any saved one. SerialFlow asks before it closes with unsaved canvas changes.
  • Take it along. Import/Export ▾ → Export Canvas (.sfcanvas)… writes the canvas and its pictures into one file; Import Canvas (.sfcanvas)… opens it as a new canvas on another PC.
  • Its own screen. Pop Out on the canvas toolbar moves the canvas into a window of its own, for a second monitor; Full Screen also maximises it there.
  • Several graphs. Each binding names its own graph letter, so one canvas can mix graphs.

Try it yourself

  1. Start SerialFlow. You don’t need to connect a port.
  2. ☰ → Tools → New Canvas Dashboard, then click Edit on the canvas toolbar.
  3. Open Documents\SerialFlow\Demo\canvas_motor_bench.txt in Notepad, select all and copy.
  4. Import/Export ▾ → Paste AI Text…: the text is already in the box. Press Import, then click Edit to leave edit mode.
  5. ☰ → Test → Delayed Playback → Demo → showcase_canvas_live.txt. The bench runs for about 18 s, trip and derate included.
  6. The layout is 1 700 pixels wide: zoom with Ctrl + mouse wheel if it does not fit.