The MDX-400 bench run is 40 minutes of thermal and battery data, then a live tail of speed steps. A graph is not a record: the Speed Control streamer keeps only its newest 800 points. So the Data Collector wrote the whole run to SQLite, CSV and JSON Lines for Python, and the Thermal & Battery graph was saved as a session and compared with a second run.
What we set up
Recording needs no firmware change: the Data Collector stores the graph lines SerialFlow already reads, from every open port. The settings are in Settings → Terminal & Data → Data Collection (or Settings… on the Data Collector panel). This run used all three formats:
| Setting | This run | Default |
|---|---|---|
| SQLite database, with One database for all runs | on, on | on, on |
CSV files (samples.csv + events.csv per run), Delimiter | on, Comma | off, Comma |
JSON Lines stream (data.ndjson per run) | on | off |
| Include computed (derived) signals | on | on |
| Record events (bookmarks, markers, graph init/clear, port connect/disconnect) | on | on |
| Start and stop automatically with the port | off | off |
| Queue Capacity / Batch Size / Flush Interval | 65536 / 2048 / 250 ms | the same |
Leave Output Folder empty to write to Documents\SerialFlow\recordings. Changes apply to the next run.

Set it up in SerialFlow
Record the run
- ☰ → View → Data Collector opens the panel. One panel records every port.
- Type a run name:
motor-bench-run. - Click ● Record.
- Run the bench. Here the 40-minute run arrived first (graphs A to D), then the live tail.
- Click ■ Stop. The run appears under Recent runs (this session). Open Folder shows the files.
Save and share a session
A .sfplot session holds one graph view: its data, the firmware’s limit lines, markers and notes, its bookmarks, the
Y range, axis label and legend the firmware set, and the view itself (zoom, lanes, styles). motor_bench_run.sfplot
is 228 KB.
- Click Save Session on the Thermal & Battery toolbar and save it as
motor_bench_run.sfplot. The dialog Save plot session starts inDocuments\SerialFlow\sessions. - Reopen it: right-click any graph and choose Open Session in New View…, then pick the file. It opens as a view of its own, named after the file.
- Send it to a colleague. The data is inside the one file, so they need no port and no recording.
The result


The run took 2 min 18 s: 18 220 samples from 10 signals on graphs A to D, 17 events, 0 dropped. Each storage row counts 18 237 items, the samples plus the events. With the default output folder, the files land here:
Documents\SerialFlow\recordings\
serialflow-recordings.sqlite every run, one file
rec-20261114-151103-186-motor-bench-run\
samples.csv events.csv data.ndjson
The recording is in long format, one row per sample. The first rows of samples.csv, and a graph B row:
timestamp_utc,port,graph,signal_id,signal_name,unit,is_computed,x,y
2026-11-05T08:58:26.8368187Z,COM4,A,1,Setpoint,rpm,0,0,0
2026-11-05T08:58:26.8384130Z,COM4,A,2,Speed,rpm,0,0,-3.6
2026-11-05T08:58:26.8394688Z,COM4,A,1,Setpoint,rpm,0,1,0
…
2026-11-05T08:58:26.8628756Z,COM4,B,2,MOSFET,°C,0,20.8667,82.44
For a spreadsheet of one graph, Export… on the graph toolbar writes the wide format, one column per signal. The
X column takes the graph’s X label and unit, Time [min] here (a graph without an X label gives plain X). Here is
motor_bench_thermal_battery.csv (CSV wide format, 1 201 rows, X in minutes):
Time [min],Motor winding [°C],MOSFET [°C],Pack voltage [V],State of charge [%]
0,23.95,24.12,52.61,98
0.0333,23.92,24.15,52.62,97.99
0.0667,23.93,24.24,52.6,97.99

motor_bench_run.sfplot reopened in a new view: 4 signals, 4 804 points, markers and notes included.Read the recording in Python
Python’s built-in sqlite3 opens the database: nothing to install. It has five tables (runs, signals,
samples, events, meta) and two views that join them:
| View | Columns |
|---|---|
v_samples | run_id, run_name, port, graph_id, signal_id, signal_name, unit, is_computed, t_utc, t_utc_ticks, x, y |
v_events | run_id, run_name, port, graph_id, kind, label, x, detail, t_utc, t_utc_ticks |
This script lists the signals, finds the hottest MOSFET sample and prints the markers on graph B:
import sqlite3
DB = "serialflow-recordings.sqlite" # in Documents\SerialFlow\recordings
RUN = "motor-bench-run"
db = sqlite3.connect(f"file:{DB}?mode=ro", uri=True) # open read-only
print(db.execute("SELECT name, sample_count, dropped_count FROM runs WHERE name = ?",
(RUN,)).fetchone())
# One row per signal: graph, name, unit, number of samples, min and max
for row in db.execute("""SELECT graph_id, signal_name, unit, COUNT(*), MIN(y), MAX(y)
FROM v_samples WHERE run_name = ?
GROUP BY graph_id, signal_id""", (RUN,)):
print("%s %-16s %-4s %5d %8.2f %8.2f" % row)
# The hottest MOSFET sample. x is the firmware's own X value: minutes on graph B
print(db.execute("""SELECT x, y FROM v_samples
WHERE run_name = ? AND graph_id = 'B' AND signal_name = 'MOSFET'
ORDER BY y DESC LIMIT 1""", (RUN,)).fetchone())
# Event markers and bookmarks that the firmware sent on graph B
for x, kind, label in db.execute("""SELECT x, kind, label FROM v_events
WHERE run_name = ? AND graph_id = 'B'
AND x IS NOT NULL ORDER BY x, kind""", (RUN,)):
print(f"{x:5.1f} min {kind:<12} {label}")
The output for this run:
('motor-bench-run', 17794, 0)
A Setpoint rpm 6187 0.00 3000.00
A Speed rpm 6187 -7.90 3129.70
B Motor winding °C 1201 23.85 70.16
B MOSFET °C 1201 24.04 82.64
B Pack voltage V 1201 44.22 52.68
B State of charge % 1201 52.92 98.00
C Ia A 145 -18.61 18.57
C Ib A 145 -18.56 18.52
C Ic A 145 -18.62 18.64
D Iβ A 181 -17.63 17.57
(20.9333, 82.64)
2.0 min EventMarker Cruise profile
15.0 min EventMarker Hill climb 150 %
16.4 min Bookmark Overcurrent trip
21.0 min Bookmark Thermal derate
21.0 min EventMarker Thermal derate
26.0 min Bookmark Regen
26.0 min EventMarker Regen
29.0 min EventMarker Cool-down
The streamer showed 800 points of Speed Control; the recording kept all 6 187. Graph D has one signal, Iβ: in
an XY frame Iα is the X value. The peak, 82.64 °C at minute 20.93, is the 82.6 °C on the graph.
Compare two runs
Run 2 is the same profile with better MOSFET cooling (heatsink v2), saved as run2_heatsink_v2.sfplot. With run 1
on screen, click Compare… on the Thermal & Battery toolbar and pick the file. Run 2 holds temperatures only, so
two traces arrive: Motor winding · v2 and MOSFET · v2. Untick the other signals in the Signals sidebar: the
MOSFET peaked at 68.1 °C instead of 82.6 °C.


Each layer gets sidebar rows with X-Offs (shift along X), Opacity (0.1 to 1.0) and Remove Layer.
Compare… also takes recorder .sqlite files (pick the run from a list), CSV, TSV, JSON Lines and JSON.
In your own firmware
Nothing extra to send: the lines that draw the graph are the lines that get recorded. From the MDX-400 feed:
| Line | Recorded as |
|---|---|
~{B:0:20.9667:70.07:82.55:44.22:62.40} | 4 rows in samples, all with x = 20.9667 |
~{B:E:3:21:Thermal derate:FF5252:D} | 1 row in events, kind EventMarker |
~{B:B:21:Thermal derate:MOSFET 82 °C - torque limited to 70 %:FFAB40} | 1 row in events, kind Bookmark |
The same lines from your own firmware, in plain C:
#include <stdio.h>
void thermal_graph_init(void) /* once, at boot */
{
printf("~{B:I:Thermal & Battery:100000:L:T:R:Time:min:0}\n");
printf("~{B:S:1:F32:R:Motor winding:°C:0:FF8A65}\n");
printf("~{B:S:2:F32:R:MOSFET:°C:0:F06292}\n");
printf("~{B:S:3:F32:R:Pack voltage:V:0:81C784}\n");
printf("~{B:S:4:F32:R:State of charge:%%:0:64B5F6}\n");
}
/* Every 2 s: 4 rows in the recording's samples table */
void thermal_sample(float t_min, float wind, float mos, float pack_v, float soc)
{
printf("~{B:0:%.4f:%.2f:%.2f:%.2f:%.2f}\n", t_min, wind, mos, pack_v, soc);
}
/* On derate: 2 rows in the events table, an event marker and a bookmark */
void thermal_derate(float t_min, float mos)
{
printf("~{B:E:3:%g:Thermal derate:FF5252:D}\n", t_min);
printf("~{B:B:%g:Thermal derate:MOSFET %.0f °C - torque limited to 70 %%:FFAB40}\n",
t_min, mos);
}
B:I makes graph B a logger (L) with time in minutes, and the B:S lines set each signal’s name, unit and colour.
B:0 sends a sample with its own X, B:E draws event marker 3 as a dashed line (D), and B:B adds a bookmark with
a comment.
Good to know
- The serial port never waits for the disk. Samples go through a queue. If the disk cannot keep up, new samples
are dropped and counted: a red Dropped counter in the panel and
dropped_countinruns. This run: 0. - Timestamps are arrival times, from a run clock that never jumps;
xkeeps the firmware’s own axis. Fed from a file, as here, all 40 minutes of graph B arrive within a second, so usex. - SQLite survives a crash or a power cut. CSV and JSON Lines can lose the last flush interval (250 ms by default) if the app crashes.
- One database for all runs puts every run in one file: filter on
run_name. Off, each run gets adata.sqlite. - Raw terminal text is not recorded. That is the job of the log file and auto-log.
- The firmware can press Record. With Settings → Terminal & Data → Device Captures ticked (it is off at
first), a line
~RecOn:motor-bench-runstarts a run with that name and~RecOffstops it. See Device commands in the manual. - Excel with a decimal comma: set the CSV Delimiter to Semicolon.
Try it yourself
- ☰ → View → Data Collector. Type
motor-bench-runas the run name and click ● Record. - ☰ → Test → Load Test File →
Demo→showcase_preload.txt. The 40-minute run fills graphs A to D. - ☰ → Test → Delayed Playback →
Demo→showcase_live.txt. When it ends, after about 1 min 50 s, click ■ Stop. - Click Open Folder and run the Python script there.
- Right-click any graph → Open Session in New View… and pick
Documents\SerialFlow\Demo\motor_bench_run.sfplot. - Click Compare… on the Thermal & Battery toolbar and pick
Documents\SerialFlow\Demo\run2_heatsink_v2.sfplot. In Signals, untick everything exceptMOSFETandMOSFET · v2.